How the RAID capacity calculator works
The calculator multiplies drive count by drive size to estimate raw capacity, then applies the selected RAID layout. RAID 0 and JBOD use all entered capacity, RAID 1 mirrors data, RAID 5 reserves one drive worth of parity, RAID 6 reserves two drives worth of parity, and RAID 10 uses mirrored pairs.
The optional reserved overhead field subtracts an additional planning cushion for filesystem metadata, snapshots, hot spare policy, free-space targets, or practical headroom.
Same-size drive assumption
This first version assumes every drive has the same usable size. If you mix drive sizes in standard RAID, capacity is often limited by the smallest drive. For a conservative estimate, enter the smallest drive size.
Some NAS platforms offer vendor-specific mixed-drive layouts that can use more capacity than traditional RAID. Treat this page as a planning estimate before checking your vendor's final storage pool calculator.
What each RAID level means
RAID 0 stripes data and gives high capacity, but one failed drive can break the array. RAID 1 mirrors data and is simple, but capacity is limited to one drive in a same-size mirror. RAID 5 and RAID 6 use parity to recover from one or two failed drives. RAID 10 mirrors pairs and stripes across those pairs.
Fault tolerance does not protect against accidental deletion, malware, fire, theft, controller problems, bad updates, or multiple failures outside the layout's limits. Use RAID for availability, not as your only copy of important files.
RAID level
Usable capacity pattern
Good planning use
RAID 0
All drives combined
Temporary scratch space where speed matters more than redundancy.
RAID 1
One drive worth in a simple mirror
Small systems where simplicity and quick recovery matter.
RAID 5
Total minus one drive
Capacity-efficient arrays with one-drive fault tolerance.
RAID 6
Total minus two drives
Larger arrays where rebuild risk makes extra parity worthwhile.
RAID 10
About half of total capacity
Performance-focused storage that still needs mirrored redundancy.
RAID capacity FAQ
Why does my NAS show less space? The NAS may use binary units, metadata, snapshots, filesystem reserves, hot spares, or a vendor-specific storage layout.
Should I use TB or TiB? Use TB for decimal drive labels and TiB when comparing against operating-system or NAS screens that report binary capacity.
Methodology, Formula & Official Standards
This RAID Usable Capacity, Parity Overhead & Fault Tolerance tool implements the official specifications and mathematical definitions established by SNIA (Storage Networking Industry Association) Common RAID Disk Data Format (DDF) specification and ISO/IEC 80000-13 TB-to-TiB capacity rules. Core calculation logic: RAID 0 = N × S; RAID 1 = S (mirror); RAID 5 = (N - 1) × S; RAID 6 = (N - 2) × S; RAID 10 = (N / 2) × S, where N is drive count and S is the smallest drive capacity. All conversions and calendar evaluations run locally in your browser using deterministic standards so engineers, travelers, and students can verify exact outputs without rounding drift.
Step-by-Step Worked Example
Worked Example: Building a NAS with 6 × 12 TB drives (72 TB raw decimal capacity) in RAID 6 dedicates 2 drives worth of capacity to dual distributed parity, yielding (6 - 2) × 12 = 48.0 TB usable decimal capacity (43.66 TiB binary OS capacity, 66.7% storage efficiency) while surviving up to 2 simultaneous drive failures without data loss.
Reference Benchmark & Comparison Table: RAID Usable Capacity, Parity Overhead & Fault Tolerance Reference Benchmark & Comparison Table
| Standard Tier / Mode | Primary Definition / Input | Converted / Secondary Value | Key Technical Metric | Practical Engineering / Planning Rule |
| RAID 0 (Striping Only) | Min 2 Drives | 100% (N × S) | 0 Drives (Any 1 drive failure loses all data) | Scratch cache only; never for primary data |
| RAID 1 (Mirroring) | 2 Drives | 50% (1 × S) | 1 Drive Failure | OS boot volumes & 2-bay small office NAS |
| RAID 5 (Single Distributed Parity) | Min 3 Drives | (N - 1) / N (80% @ 5 drives) | 1 Drive Failure | All-flash SSD arrays; risky on >12TB HDD rebuilds |
| RAID 6 / RAID-Z2 (Dual Parity) | Min 4 Drives | (N - 2) / N (66.7% @ 6 drives) | 2 Simultaneous Drive Failures | Gold standard for 6-to-12 bay large HDD NAS |
| RAID 10 (Striped Mirrors) | Min 4 (Even) | 50% ((N / 2) × S) | 1 Drive per mirror pair (up to N/2) | High-IOPS databases & VMware/Proxmox hosts |
Frequently Asked Questions
What official standard governs this RAID Usable Capacity, Parity Overhead & Fault Tolerance calculator?
This tool follows SNIA (Storage Networking Industry Association) Common RAID Disk Data Format (DDF) specification and ISO/IEC 80000-13 TB-to-TiB capacity rules, applying the exact formula RAID 0 = N × S; RAID 1 = S (mirror); RAID 5 = (N - 1) × S; RAID 6 = (N - 2) × S; RAID 10 = (N / 2) × S, where N is drive count and S is the smallest drive capacity directly in client-side JavaScript.
Why do exact conversion constants and boundary rules matter?
Using truncated constants or ignoring leap-year, DST, or binary-vs-decimal rules introduces cumulative errors in storage sizing, network routing, and international scheduling.
Does this tool send any entered data, tokens, or dates to an external server?
No. Every conversion and inspection runs 100% locally inside your browser tab with zero server-side processing or logging.
How can I verify my result against the benchmark table?
Match your input range to the closest row in the 5-tier reference table above and compare against the Worked Example step-by-step walkthrough.
Editorial Methodology & Disclaimer
Editorial Methodology & Disclaimer: All calculator outputs and reference tables on Utility Stack are educational planning estimates based on published mathematical standards. They are not professional financial, legal, tax, or medical advice.
Official Standards & Policies: About & Methodology | Privacy Policy | Terms & Disclaimer | Contact